AXISA1001NetworkDoorController&AXISEntryManager
SystemConfiguration
-Opencircuit=OpendoorSelectifthedoormonitorcircuitisnormallyclosed.Thedoormonitorgivesthedoor
opensignalwhenthecircuitisopen.Thedoormonitorgivesthedoorclosedsignalwhenthecircuitisclosed.
CancelaccesstimeoncedoorisopenedSelecttopreventtailgating,thatis,stopunauthorizedvisitorsfromaccessing
thedoor.Thedoorwilllockimmediatelyafterthedoorhasbeenopened.Whenthedoorcloses,thedoorwillbelockedand
cannotbeopeneduntilauserrequestsandisgrantedaccessagain.
Thefollowingdoormonitortimeoptionsareavailable:
AccesstimeSetthenumberofsecondsthedoorshallremainunlockedafteraccesshasbeengranted.Thedoorremains
unlockeduntilthedoorhasbeenopenedandwilllockwhenitclosesregardlessofwhethertheaccesstimehasexpiredor
not.Ifthedoorremainsunopened,itlockswhenthesetaccesstimehasbeenreached.
OpentoolongtimeSetthenumberofsecondsthedoorisallowedtostayopen.Ifthedoorisstillopenwhenthe
opentoolongtimehasbeenreached,thedooropentoolongalarmistriggered.Setupanactionruletocongurewhich
actiontheopentoolongeventshalltrigger.
Pre-alarmtimeApre-alarmisawarningsignalthatistriggeredbeforetheopentoolongtimehasbeenreached.It
tellstheadministratorand,dependingonhowtheactionrulehasbeensetup,itcanalsowarntheuser(theperson
enteringthedoor)thatthedoorneedstobeclosedortherealalarm,thedooropentoolongalarm,willgooff.Setthe
numberofsecondsbeforethedooropentoolongalarmistriggeredthesystemshallgivethepre-alarmwarningsignal.
Todisablethepre-alarm,setthepre-alarmtimeto0.
Forinformationabouthowtosetupanactionrule,seeSetUpActionRulesonpage34.
LockOptions
DeselectDoormonitortomakethefollowinglocktimeoptionsavailable:
DoorunlockedtimeSetthenumberofsecondsthedoorshallremainunlockedafteraccesshasbeengranted.Thedoor
remainsunlockeduntilthedoorhasbeenopenedandwilllockwhenitclosesregardlessofwhetherthedoorunlockedtime
hasexpiredornot.Ifthedoorremainsunopened,itlockswhenthesetdoorunlocktimehasbeenreached.
Pre-locksignaltimeApre-locksignalisawarningsignalthatistriggeredbeforethedoorlocks.Ittellstheadministrator
and,dependingonhowtheactionrulehasbeensetup,itcanalsowarntheuser(thepersonenteringthedoor)that
thedoorwilllocksoon.Setthenumberofsecondsbeforethedoorlocksthesystemshallgivethepre-lockwarning
signal.Thepre-locksignaltimemustbeshorterthanthedoorunlockedtime.Todisablethepre-lockwarningsignal,
setthepre-locksignaltimeto0.
Thefollowinglockcircuitoptionsareavailable:
12V
-Fail-secureSelectforlocksthatremainlockedduringpoweroutages.Whenapplyingelectriccurrent,the
lockwillunlock.
-Fail-safeSelectforlocksthatunlockduringpoweroutages.Whenapplyingelectriccurrent,thelockwilllock.
RelayCanonlybeusedononelockperdoorcontroller.Iftwodoorsareconnectedtothedoorcontroller,arelaycan
onlybeusedonthelockoftheseconddoor.
-Relayopen=LockedSelectforlocksthatremainlockedwhentherelayisopen(fail-secure).Whenthe
relaycloses,thelockwillunlock.
-Relayopen=UnlockedSelectforlocksthatunlockduringpoweroutages(fail-safe).Whentherelaycloses,
thelockwilllock.
NoneSelectifonlyonelockwillbeused.
Thefollowinglockmonitoroptionsareavailable:
LockmonitorSelecttomakethelockmonitorcontrolsavailable.Thenselectthelockthatshallbemonitored.Alock
monitorcanonlybeusedondouble-lockdoorsandcannotbeusediftwodoorsareconnectedtothedoorcontroller.